Proteccio Bull

Description

Use this procedure to install Proteccio Bull middleware from the Stream Offline CA appliance and configure Stream with a Proteccio PKCS#11 keystore.

Pre-requisites

Prepare approved Proteccio middleware, the vendor device prerequisites, client configuration, and the target PKCS#11 library and slot values. Boot Stream Offline CA in Create or Restore; the image already includes the generic tools used for slot inspection.

Values to confirm

Value Purpose Record in the ceremony report

Proteccio runtime

Install the Proteccio client runtime and libraries from HSM > INSTALL > PROTECCIO.

ISO filename, version, and SHA-256 hash.

Client configuration

Connect the appliance runtime to the approved Proteccio environment.

Configuration source and non-secret target identifier.

Virtual HSM or slot

Select the Proteccio token used by the Stream PKCS#11 keystore.

Virtual HSM or slot identifier, user type, and policy reference.

PKCS#11 library path

Configure the Stream PKCS#11 keystore.

Library path and parse result.

HSM backup policy

Confirm how Proteccio state is backed up and restored outside Stream state.

Backup policy reference and backup record identifier.

Middleware installation

  1. On tty1, open HSM > INSTALL > PROTECCIO.

  2. Select the approved Proteccio middleware ISO.

  3. Before installation starts, enter and review all values required for proteccio.rc: HSM IP address, SSL mode, client mode, logging level, log path and, when SSL is enabled, the selected certificate and key paths.

  4. Apply the configuration summary. Cancelling this step leaves the middleware uninstalled.

  5. Let the appliance install the Proteccio client runtime, PKCS#11 library, and client tools, then write and verify proteccio.rc automatically.

  6. Confirm that the automatic installation completes and that the PKCS#11 library and client tools are available.

  7. Record the runtime package, configuration source, and non-secret validation output in the ceremony report.

No manual middleware installation is required on the appliance when the approved Proteccio ISO is supplied. The Proteccio flow follows the same appliance-driven installation model as nShield Edge and Thales Luna.

The default runtime values are:

Item Default value

ISO mountpoint

/mnt/proteccio

Installer log

/opt/offline_ca/log/proteccio-install.log

PKCS#11 library

/opt/tw_proteccio/lib/libnethsm.so

Client configuration marker

/etc/proteccio/proteccio.rc

Slot-listing log

/opt/offline_ca/log/proteccio-slots.log

After the configuration has been collected and confirmed, the installer mounts the ISO read-only, runs the vendor install script through an expect helper, unmounts the ISO on exit, writes proteccio.rc, then verifies the PKCS#11 library and client configuration marker.

Configure the Stream keystore

  1. In Stream, open Keystores and keys.

  2. Add a PKCS#11 keystore.

  3. Enter the approved Proteccio PKCS#11 library path.

  4. Parse the library.

  5. Select the approved slot.

  6. Enter the approved user type and PIN.

  7. Save the keystore.

  8. Verify that Stream can access the expected slot.

The exact Proteccio PKCS#11 library path, slot selection, and HSM backup procedure depend on the target Proteccio configuration and must be confirmed before production use.

Slot inspection

After Proteccio middleware is installed, the top-level PROTECCIO menu appears in the Create, Restore, and post-start console menus. Slot inspection is centralized in the generic PKCS#11 operations menu. Use PKCS11 > DISCOVERY > PROVIDER-SLOTS, then select PROTECCIO, to list visible Proteccio PKCS#11 slots before configuring or validating the Stream keystore.

The appliance verifies the middleware and shared slot-listing helper, displays the result on tty1, and retains a diagnostic log.

After installation, PROTECCIO keeps the provider context available. Use PKCS11 > DISCOVERY > PROVIDER-SLOTS to list slots, and the generic PKCS11 menu for diagnostics, approved public-object transfers, CSR generation, and reports. Private-key transfer, token reset, PIN administration, key wrapping, object move or copy, and attribute changes remain outside this workflow.

Record slot identifiers and non-secret validation output only. Do not record PINs, device secrets, or authentication material.

Verification

Before production, confirm that installation completes, the client tools are available, the expected slot is visible, and Stream can parse the library and access the selected token. Validate key generation, signing, backup, and restore on the target hardware.